Explosion-proof Thermoelectric Barrier Explosion-type Thermocouple Temperature Transmitter Pt100 Temperature Sensor WZP-240

Explosion-proof Thermoelectric Barrier Explosion-type Thermocouple Temperature Transmitter Pt100 Temperature Sensor WZP-240


カテゴリー:

説明

Explosion-proof Thermoelectric Barrier Explosion-type Thermocouple Temperature Transmitter Pt100 Temperature Sensor WZP-240
製品説明
Pt100 Temperature Sensor WZP-240
Pt100 Temperature Sensor WZP-240
Explosion-proof Thermoelectric Barrier Explosion-type Thermocouple Temperature Transmitter Pt100 Temperature Sensor WZP-240
The WZP-240 integrated explosion-proof thermal resistance adopts the PT100 platinum resistance temperature measurement technology.Based on the linear characteristics of platinum metal resistance and temperature, it achieves precise temperature detection within the range of -200 ℃ to +500℃ (accuracy grade A, error ±0.15%). Its flameproof structure complies with the GB3836 standard, with anexplosion-proof grade of dⅡBT4. It is suitable for explosive gas environments of Class ⅡB (ignition temperature ≥T4) and can operate safely in high-risk scenarios such as chemical engineering, petroleum, and metallurgy.
Pt100 Temperature Sensor WZP-240

特徴

★ Imported original platinum resistance (Pt100/Pt1000), 良い一貫性;★ High temperature measurement accuracy and reliable performance;★ Two-layer package, 優れた防振性能;★ High mechanical strength and good pressure resistance;★ Standard pipe thread installation.
仕様
アイテム
価値
type
Immersion Heater
power source
電気の
電圧
24V
Heating capacity
-50-200℃
warranty
2 年
material
ステンレス鋼
重さ (KG)
2
place of origin
中国,江蘇省
brand name
VANORM
working temperature range
-200~600℃
key selling points
Eco-Friendly, Automatic, 高い正確性, Competitive Price
machinery test report
提供された
video outgoing-inspection
提供された
温度範囲
medium-temperature
詳細画像
Pt100 Temperature Sensor WZP-240
Pt100 Temperature Sensor WZP-240

Precautions

1.Choose a place that is easy to operate and maintain for installation
2. It should be installed as far away as possible from vibration sources
3.It should be installed as far away as possible from heat sources
4. It can be directly installed on pipelines or equipment. During installation, it should be clamped tightly at the hexagonal position of the transmitter by hand, such as a wrench.
5. When handling and installing the transmitter, care should be taken to avoid collisions that may affect the performance of the circuit.
6. There is an isolation diaphragm inside the pressure inlet of the transmitter. Do not touch it with foreign objects by humans.
7. The external thread of the transmitter must be sealed properly; otherwise, it will cause inaccurate and unstable pressure.
8. Safety barriers must obtain explosion-proof qualification certificates, and their installation should be carried out in accordance with the requirements of their instructions.
関連製品
Pt100 Temperature Sensor WZP-240
Pt100 Temperature Sensor WZP-240
Pt100 Temperature Sensor WZP-240
お客様の評価
Pt100 Temperature Sensor WZP-240
パッキング & 配達

Product Packaging Solutions

1.Our services include individual unit packaging with optional labeling to streamline operations and reduce time costs.
2.We provided fumigated solid wood pallets for heavy-duty exports and durable plywood crates for lighter loads, exempt from fumigation.
3.All solutions adhere to international trade standards, including certification for shipments to the US, カナダ, and the EU, ensuring seamless customs clearance and pest control compliance.
Pt100 Temperature Sensor WZP-240
Pt100 Temperature Sensor WZP-240

Our core competencies:

1.Vertical Manufacturing Expertise:The factory which we cooperated with operating professional production facilities, they maintain full control over Research and development. This vertical integration ensures stringent quality compliance (ISO 9001, CE,CQC,Rohs, UL) and enables competitive pricing without intermediaries.
2.Dual-Channel Procurement Solutions:Direct OEM Services, Customize heating systems and linear slot diffusers to meet project-specific airflow and thermal requirements.
3.Direct OEM Services: Customize heating systems and linear slot diffusers to meet project-specific airflow and thermal requirements.
4.Technical Partnership Model:Beyond transactional engagements, we provide ventilation system design and Energy efficiency audits for heating solutions,multilingual after-sales technical support.
5.Innovation and Sustainability:Investing 8% of annual revenue in R&D to be committed to creating better new products.
Pt100 Temperature Sensor WZP-240
認証
Pt100 Temperature Sensor WZP-240
よくある質問

1. Q:私たちは誰ですか?

あ:Our factory was established in 1996, and the foreign trade sales team was established in 20212.Q: 独自のフォワーダーを使用できますか?
あ: もちろん. We can ship it to them.
3.私たちが提供できるサービス?受け入れられた配送条件: FOB,CFR,CIF,EXW,速達便;受け入れられる支払い通貨:米ドル,HKD,人民元;受け入れられる支払いタイプ: T/T, ペイパル, 現金;話される言語: 英語,中国語
4. Q: 注文方法?
あ: Please email your order to us and we will confirm with you.
見積前, 製品情報を確認させていただきたいのですが, such as size and quantity. いかなる場合でも, 電子メールまたはオンラインメッセージで直接ご連絡ください.
5. Q: 品質をどのように保証するか?
あ: 私たちは生産の品質管理基準を厳格に遵守しています; 毎回ワークショップをチェック 2 時間; 独自の研究開発チームと研究所を持っています.
6. Q:私たちから何を購入できますか?
あ: Electrical appliances and Ventilation Product; 他にニーズがあれば, お客様の購入をお手伝いすることもできます.

レビュー

まだレビューはありません.

最初にレビューしてみませんか?Explosion-proof Thermoelectric Barrier Explosion-type Thermocouple Temperature Transmitter Pt100 Temperature Sensor WZP-240