500C High Temperature Fiberglass Braid Heating Belt/electric Power Cable Heat Trace Cable Heating Tape for Pipeline

500C High Temperature Fiberglass Braid Heating Belt/electric Power Cable Heat Trace Cable Heating Tape for Pipeline


Beskrivelse

500C High Temperature Fiberglass Braid Heating Belt/electric Power Cable Heat Trace Cable Heating Tape for Pipeline
Produkt beskrivelse
500C High Temperature Fiberglass
500C High Temperature Fiberglass
Fibergalss Electric Heating Cable
Fiberglass electric heating cable is suitable for heating and heat preservation of tanks, rør, tanks and other containers ofvarious industrial equipments. It is mainly composed of electrothermal materials and insulating materials. The electrothermalmaterials are nickel-chromium alloy belts, which have fast heat generation and high thermal efficiency.
Long service life, the insulation material is multi-layer alkali-free glass fiber, with good temperature resistance and reliableinsulation performance. The utility model has the advantages of soft structure, can be directly wound on the surface of the heatedpart when used, and has uniform temperature, simple installation, convenient use, safety and reliability.
500C High Temperature Fiberglass
Specifikation
Structural Performance(1) It is mainly composed of nickel-chromium alloy wires and insulating material, and has fast heating speed, high heat efficiency and long service life.(2) Alkali-free glass fiber core rack is wound with electric heating wires, fiberglass is used as main insulation, the heatresistance performance is excellent, and the insulation performance is reliable.(3) It has great flexibility, and can be directly wound on a to-be-heated device, with good contact and uniform heating.Note: fiberglass heating cable do not have the functions of waterproof and moistureproof .
500C High Temperature Fiberglass
Produkt
Spænding(V)
Watt(W)
Width(mm)
Isolationsmodstanden
Maksimal temperatur
RDG–1
220
100
10-30
>2MΩ
≤500℃
RDG–2
220
200
10-30
RDG–3
220
300
10-30
RDG–4
220
400
10-30
RDG–5
220
500
10-30
RDG–6
220
600
10-30
RDG–7
220
700
10-30
RDG–8
220
800
10-30
RDG–9
220
900
10-30
RDG–10
220
1000
10-30
Installations instruktioner
Step 1: Pipe Surface PreparationPrepare surface to be heated: Wipe the surface making sure there is no foreign material, like liquid, on the surface. Foreignmaterial inhibits heat transfer and liquid can damage select models of heating tape (i.e. HighTemperature Heating Tapes).Make a visual inspection of heating tape: We recommend that you replace the heating tape if it becomes torn or damaged. Damaged heating tape is a safety hazard and will not operate correctly.Step 2: Heating Tape Installation (wrap)Heating tape can be installed on nearly any surface due to its flexibility. Spiral wrap the heating tape onto the surface to beheated so that the length of one entire side of the heating tape is in full contact with the surface .The distance between spiral wraps is dependent on the uniformity requirements and the amount of available heating tape. A minimum distance of 1/8” is required between spiral wraps to avoid damage to the heating tape.Attach the heating tape to the surface by either using built-in tie straps, high-temperature adhesive tape or mechanical clamping devices that will not cause damage to the heating tape.Ensure the heating tape is not kinked, twisted, or hanging free from the surface.Do not overlap heating tape on itself.This can cause damage to the heating tape due to overheating.Step 3: Connecting Your Heating Tape to a Temperature Controlling DeviceYour heating tape must be connected to an external temperature control device. Ensure your temperature controller is protected by a properly sized circuit breaker or fuse. Use of a ground fault circuit interrupter is highly recommended and may be required for your installation.For proper temperature control, secure a thermocouple, RTD, or other sensing device with one strip of adhesive tape so that it is in close proximity to the heater to prevent overheating.
Pakning & Levering
500C High Temperature Fiberglass
500C High Temperature Fiberglass
500C High Temperature Fiberglass
FAQ
1. Hvem er vi?Vi er baseret i Jiangsu, Kina, start fra 2010, sælg til Oceanien(50.00%),Nordamerika(30.00%),Sydamerika(10.00%),Sydeuropa(10.00%). Der er i alt ca 11-50 mennesker på vores kontor.2. hvordan kan vi garantere kvalitet?Altid en præproduktionsprøve før masseproduktion;Altid sidste inspektion før forsendelse;3.hvad kan du købe hos os?Patronvarmer/indstøbt varmelegeme/cirkulationsvarmelegeme/motorblokvarmer/åben spolevarmer, Finnvarmer/Stripvarmer/Varmeelement4. hvorfor skal du købe hos os ikke fra andre leverandører?1.Mere end 40 års erfaring
2.UL CE RoHS CQC ISO9001:2008
3.R&D hold
4.Giv testrapport
5.Support produktdesign5. hvilke tjenester kan vi levere?Accepterede leveringsbetingelser: FOB,CFR,CIF,EXW,DDU,Hurtiglevering;Accepteret betalingsvaluta:USD,EUR,CNY;Accepteret betalingstype: T/T,L/C,D/P D/A,MoneyGram,Kreditkort,PayPal,vestlige Union,Kontanter,Escrow;Talt sprog:engelsk,kinesisk,fransk

Anmeldelser

Der er ingen anmeldelser endnu.

Vær den første til at anmelde “500C High Temperature Fiberglass Braid Heating Belt/electric Power Cable Heat Trace Cable Heating Tape for Pipeline